Gas Venting Installation Manuals

Centrotherm
IBC
Duravent
IPEX
Fields Controls
Rheem
Hart & Cooley
Selkirk
Z-Flex

Make up Air for Combustion

Sizing Louvered Grilles

Minimum Required Volume of Air:

50 Cubic Feet Per 1,000 BTU’s (50 x CFH)

or L x W x H [max 8FT] x 20 = Total BTU’s Area Will Support

Excel Spreadsheet for Calculating Combustion Make Up Air & Common Vent Connector Sizing

↑ Back To Top ↑

Centrotherm InnoFlue Installation Instructions- Single Wall Rigid, Flex and Concentric Vent Systems:

Supports on pg. 6; Pitch on pg. 7 Must use rubberized clam shell supports.

 Centrotherm Approval List of Appliance Manufacturers AND Appliance adapter p/n if required

 Letter from Centrotherm regarding being used on Category 3 Appliances- from Inspector #44 Cont. Ed

↑ Back To Top ↑

Duravent PolyPro Installation Instructions- Pitch on pg. 8; supports on pg. 9

Letter from Duravent regarding polypro being used on Category 3 Appliances- from Inspector #44 Cont. Ed

↑ Back To Top ↑

SWG Powervent Installation Manual- clearances on pg. 5

SWG Powervent Troubleshooting and Maintenance Guide

Water Heater Control Kit Instructions

Fan in the Can CAS-34U Instructions

Fan in the Can CAS-34U BTU limits & Max pipe length chart from manual pg.4

SWG Powervent sizing chart

Gas Vent Damper Instructions. Troubleshooting pg.9 New motor is p/n GVD-RMA

↑ Back To Top ↑
↑ Back To Top ↑

Letter from IBC regarding no limit on exposed vent piping outside.

IBC Installation Manuals

↑ Back To Top ↑

System 1738

System 1738 Brochure

Flue Gas Venting Approved Appliance Manufactures List Effective Nov 2023

System 1738 Installation Manual-

Pitch on pg.3 (j.); Dryer clearance page 4 (d).; Supports on page 9 & 10; Unconditioned space on page 4.(c)

Letter from IPEX regarding attaching to unlisted PVC and CPVC- received from Jeff Damario, GEM Plumbing

System 1738 Pipe Product Update: April 10, 2024

Technical Service Bulletin Regarding Drilling into Pipe for Combustion Tests

System 1738 Installation Instructions for 2”, 3" and 4" PVC LOW PROFILE Vent Terminations WITH CLEARANCES
System 1738 Installation Instructions for CONCENTRIC Vent Terminations WITH CLEARANCES

System  636

System 636 Brochure

System 636 Installation Manual-Pitch on page 2 (k); Dryer clearance page 4 (i).; Unconditioned space on page 4 (k); Supports on page 6 & 7; Termination Clearances Page 25

↑ Back To Top ↑

E-mail from Walter Morris manufacture’s rep for Rheem and IPEX regarding venting Category 3 power vent water heater with IPEX System 1738

Letter from Rheem regarding venting with UL-1738 and 636 materials including PVC, CPVC and Polypropylene-received from Walter Morris, manufacture’s rep.

↑ Back To Top ↑
↑ Back To Top ↑